Type of measurement | TRMS AC+DC |
Digits | 1200000 |
Bandwidth VAC | 300 kHz |
Bandwidth AAC | 5 kHz |
VAC max. | 600 VAC |
VAC resolution | 0.1 μV |
VDC max. | 600 VDC |
VDC resolution | 0.1 μV |
ADC max. | 1 ADC |
ADC resolution | 0.0001 μA |
AAC max. | 1 AAC |
AAC resolution | 0.0001 μA |
Ohm max. | 10 MOhm |
Ohm resolution | 0.1 mOhm |
Hz max. | 100 kHz |
Hz resolution | 0.00001 Hz |
°C measurement range | -270...+1372 °C |
°C resolution | 0.01 °C |
Sensor type/thermocouples |
PT100
PT1000 J K |
Measuring function |
Data logger
Diode tester |
Instrument functions | Frequency counter |
Interfaces |
RS232
USB IEEE-488 (Optional) |
Measuring error, DC volt | 0.003% |
Measuring error, AC volt | 0.8% |
Measuring error, DC ampere | 0.02% |
Measuring error, AC ampere | 0.2% |
Measuring error, resistance | 0.005...0.5% |
Electrical supply |
115 VAC
230 VAC |
Dimensions L x W x H | 365 x 285 x 75 mm |
Weight | 3 kg |
Description | Bench multimeter |
Design | Bench |
Delivery with |
Digital cable
Manual Power cable Test lead |