Holding current @ 23°C | 0.12 A |
Rated voltage | 9 VDC |
Tripping current | 0.5 A |
Max. current | 100 A |
Time to trip | 0.02 s |
Construction form | 0805 |
Holding current @ 60°C | 0.12 A |
Temperature range | -40...+85 °C |
Resistance min. | 0.65 Ohm |
Resistance max. | 3.5 Ohm |
IEC-climate category | 40/85 (+85 °C @ 85% R.H, 1000 h) |