Primary rated current | 600 A |
Output | ±4 V |
Height | 50 mm |
Length | 72 mm |
Operating voltage | ±12...15 V (±5%) |
Measuring range | ±900 A |
Bandwidth | DC...8 kHz |
Mounting | Screws |
Dimensions, bushing | 41 x 12.5 mm |
Test voltage, primary/secondary | 3 kV |
Operating temperature | -10...+70 °C |
Dimensions L x W x H | 72 x 32.4 x 50 mm |
Response time | 10 μs @ 90 % of nominal primary current |
Accuracy | ±2 % @ nominal primary current, TA = 25 °C, ±15 V (±5 %) |
Output voltage | ±4 V @ nominal primary current, RL = 10 kOhm, TA = 25 °C |